Chapter 12 Description of Parameter SettingsMH300
12.2-22
Parameter Description Unit Default Settings
05-07
Rotor resistance (Rr) for induction
motor 1 (Ω)
Ω 0.000 0.00065.535
05-08
Magnetizing inductance (Lm) for
induction motor 1 (mH)
mH 0.0 0.06553.5
05-09
Stator inductance (Lx) for induction
motor 1 (mH)
mH 0.0 0.06553.5
10-25
FOC bandwidth for speed
observer
Hz 40.0 20.0100.0
11-00 System control 513 0–65535
11-01 Per unit of system inertia pu 256 1–65535
11-02 ASR1 / ASR2 switch frequency Hz 7.00 5.00599.00
11-03 ASR1 low-speed bandwidth Hz 10
1–40 Hz (IM) /
1–100 Hz (PM)
11-04 ASR2 high-speed bandwidth Hz 10
1–40 Hz (IM) /
1–100 Hz (PM)
11-05 Zero-speed bandwidth Hz 10
1–40 Hz (IM) /
1–100 Hz (PM)