EasyManua.ls Logo

Delta MH300 Series - Page 648

Delta MH300 Series
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 12 Description of Parameter SettingsMH300
12.2-29
Load operation adjustment
1. Load operating test
B1. Low-frequency loading performance, when the switch frequency is below Pr.10-39:
a. When the low-frequency cannot start the motor with load, or the rotor speed is not smooth,
increase Pr.11-03 (ASR1 low-speed bandwidth) or Pr.11-01 (per-unit of system inertia); if
the above adjustment cannot meet the requirement, then increase Pr.10-32 (PM FOC
sensorless speed estimator bandwidth).
b. When frequency outputs, low-frequency operating current is large or an oc error occurs,
decrease Pr.11-03 and Pr.11-01; or decrease Pr.10-32.
B2. Acceleration performance test under heavy-load status, accelerate the motor to rated rotor
speed according to the acceleration time:
a. If the motor cannot follow the acceleration time, and the response is too slow, increase
Pr.11-04 (ASR2 high-speed bandwidth) and Pr.11-03 (ASR1 low-speed bandwidth).
b. If an excessive acceleration causes vibration or ocA error, decrease Pr.11-04 and Pr.11-
03.
2. Stability test at constant speed operation: if the motor operates stably at constant speed
a. If the motor output rotor speed presents periodic low-frequency wave, increase Pr. 10-34
(PM sensorless speed estimator low-pass filter gain), or increase Pr. 10-32 (PM FOC
sensorless speed estimator bandwidth).
b. If the output frequency reflects high-frequency vibration, decrease Pr. 10-34 or decrease
Pr. 10-32.
IPM Sensorless adjustment parameters
Refer to Section 12-1 Description of Parameter Settings for more details.
Parameter Description Unit Default Setting Range
Pr.10-32
PM FOC sensorless speed estimator bandwidth
Hz
5.00
0.00600
Pr.10-34 PM sensorless speed estimator bandwidth N/A 1.00 0.00655.35
Pr.10-35 AMR (Kp) gain N/A 1.00 0.003.00
Pr.10-36
AMR (Ki) gain
N/A
0.20
0.003.00
Pr.10-39
Frequency point to switch from I/F mode to PM
sensorless mode
Hz 20.00 0.00599
Pr.10-40
Frequency point to switch from PM sensorless
mode to V/F mode
Hz 20.00 0.00599
Pr.10-42 Initial angle detection pulse value N/A 1.0 0.03.0
Initial Angle Estimating Parameters
Pr.10-51
Injection frequency (for IPM)
Hz
500
0–1200
Pr.10-52 Injection magnitude (for IPM) V
15.0 /
30.0
0.0200.0
Pr.10-53
PM initial rotor position detection method
N/A
0
0–3
Motor Performance Control Parameters
Pr.11-00
System control
bit
0
0–7
Pr.11-02 ASR1 / ASR2 switch frequency Hz 7 5.00599
Pr.11-03 ASR1 low-speed bandwidth Hz 10
1–100 (PM)
1–40 (IM)
Pr.11-04 ASR2 high-speed bandwidth Hz 10
1–100 (PM)
1–40 (IM)
Pr.11-05 Zero-speed bandwidth Hz 10
1–100 (PM)
1–40 (IM)

Table of Contents