Chapter 13 Warning Codes|MH300
13-40
ID No.
Display Warning Name Description
50
PLC
opposite defect
(PLod)
PLC download error warning
Action and Reset
Action condition
During PLC
downloading, the program source code detects incorrect
address (e.g. the address exceeds the range), then the PLod warning
shows.
Action time Immediately displays when the fault is detected
Warning setting parameter N/A
Reset method
Check if the program is correct and re-download the program. If the
fault
does not exist, the warning automatically clears.
Reset condition N/A
Record N/A
Cause Corrective Actions
Incorrect component number is
found when downloading the
PLC program
Use the correct component number.