EasyManua.ls Logo

Delta MH300 Series - Page 768

Delta MH300 Series
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 14 Fault CodesMH300
14-41
ID No.
Display Fault Name Description
31
EEPROM read error
(cF2)
Internal EEPROM cannot be read.
Action and Reset
Action condition Firmware internal detection
Action time cF2 acts immediately when the drive detects the fault.
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Immediately reset
Record Yes
Cause Corrective Actions
Internal EEPROM cannot be
read.
Press RESET key. If cF2 error still displays on the keypad
, return to the
factory for repair.
Reset the parameter to the default setting. If cF2 error still
displays on the
keypad, return to the factory for repair.
Cycle the power. If cF2 error still exists, return to the factory for repair.