Chapter 16 PLC Function ApplicationsMH300
16-34
Special M Function Descriptions R/W
M1032 -- --
M1033 -- --
M1034 -- --
M1035 -- --
M1036 -- --
M1037 -- --
M1038 MI7 single-phase or MI6+MI7 AB-phase count begins RW
M1039 Reset MI7 single-phase or MI6+MI7 AB-phase count value RW
M1040 Hardware power (Servo On) RW
M1041 -- --
M1042 Quick Stop RW
M1043 -- --
M1044 Pause (Halt) RW
M1045
M1047
-- --
M1048 -- --
M1049 -- --
M1050 -- --
M1051 -- --
M1052 Lock frequency (lock, frequency locked at the current operating frequency) RW
M1053 -- --
M1054 -- --
M1055 -- --
M1056 Hardware already has power (Servo On Ready) RO
M1057 -- --
M1058 On Quick Stopping RO
M1059
M1062
-- --
M1063 Torque reached RO
M1064
M1076
-- --
M1077 485 read / write completed RO
M1078 485 read / write error RO
M1079 485 communication time-out RO
M1080 485 exception error RO
M1081 485 check sum or data format is wrong RO
M1085 485 data have been updated RW