Chapter 16 PLC Function ApplicationsMH300
16-56
API
FEND
End
of a main program
06
bit device
Word device
16-bit command (1 STEP)
FEND
Continuous
execution type
32-bit command
Flag signal: none
X
Y
M
K
H
KnX
KnY
KnM
T
C
D
Notes on operand usage:
No operand
A contact-driven command is not needed.
This command indicates the end of the main program. It is the same as the
END command when the PLC executes this command.
The CALL command program must be written after the FEND command, and
the SRET command is added to the end of the subprogram.
When using the FEND command, an END command is also needed.
However, the END command must be placed at the end, after the main
program and subprogram.