Chapter 16 PLC Function ApplicationsMH300
16-72
API
EZCP
Compare binary floating point number range
111
D
P
bit device
Word device
16-bit command
32-bit command (17 STEP)
DEZCP
Continuous
execution type
DEZCPP
Pulse
execution type
Flag signal: none
X
Y
M
K
H
KnX
KnY
KnM
T
C
D
S1
S2
S
D
Notes on operand usage:
The operand D occupies three consecutive points.
Refer to the
function specifications table for each device in series for the scope
of device usage.
S
1
: Lower limit for binary floating point number in range comparison. S
2
: Upper
limit for binary floating point number in range comparison. S: Compari
son of
binary floating point numerical values. D: Results of comparison, occupies three
consecutive points.
Compares binary floating point number S with the lower limit value S
1
and the
upper limit value S
2
; stores the results of comparison in D.
If the source operand S
1
or S
2
designates a constant K or H, the command
converts the constant to a binary floating point number for the purpose of
comparison.
When the lower limit S
1
is greater than the upper limit S
2
, a command issues to
perform comparison using the lower limit value S
1
as the upper and lower limit.
When the designated device is M0, it automatically occupies M0M2.
When X0=ON, the DEZCP command executes, and one of M0M2 is ON. When
X0=OFF, the EZCP command does not execute, and M0M2 remain
s in the
X0=OFF state.
Use the RST or ZRST command to clear the result.