Parameter Possible Values Default Rev HHP Lite Std Adv
Speed x Turn for Grip 5 – 100 % 100 % C -
Speed X Turn for Grip is the absolute maximum speed/turn product for which the
chair is stable on a surface with good grip. The DX System limits the turning speed
when the forward speed is too high, and it limits the forward speed when the turning
speed is too high.
100%
50%
20%
5%
Speed x Turn
100%
forward
speed
100%
turning
speed
The speed limiting does not limit the physical joystick position, but it limits the chair
response. For example, with a 5% Speed X Turn for Grip value, if a powerchair travels
at full speed forward and the joystick suddenly demands a sharp right turn, the chair
will first slow down before it starts to turn.
Forward
75
Note:
The actual chair response can be limited by other factors or
parameters (for example the acceleration parameters, the damping
point or the other chair stability parameters), and therefore the
actual response path can be inside the limit curves. The path will
never go outside the limit curve, however.
Actual
chair response
Joystick
movement
Restrictor
plate
Left Right
Reverse

Table of Contents

Other manuals for Dynamic DX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic DX and is the answer not in the manual?

Dynamic DX Specifications

General IconGeneral
BrandDynamic
ModelDX
CategoryNetwork Router
LanguageEnglish

Related product manuals