D 20 14
Setting menu 600 -
compacting element
frequencies
Menu for setting the compac-
tor frequencies:
- (1) nominal tamper number
of revs. (RPM) display
and adjustment parame-
ters
- (2) nominal vibration
number of revs. (RPM) dis-
play and adjustment pa-
rameters
- (3) nominal auxiliary com-
pactor number of revs.
(RPM) display and adjustment parameters
A
Tamper, vibration and auxiliary compactor adjustment range depending on screed
type. (Follow screed manual)
m
On switching to a different type of course in set-up menu 501, the screed parameters
are automatically switched to the values last set up for the corresponding type of
course!
Setting menu 601 -
delayed screed start
Menu for setting the
screed starting delay:
- (1) delay duration (sec.)
display and adjustment pa-
rameters
A
On swivelling the drive lever,
the floating function of the
screed is only activated once
the set time has elapsed.
A
Setting range 0-60 sec.
1
2
3
1