D 43 13
Oil pressure indicator lamp for the travel drive (87)
- Must go out after starting.
m
If the lamp does not go out:
Do not switch on the traction drive! Otherwise, the entire hydraulic system could be
damaged.
When the hydraulic oil is cold:
- Activate set-up mode function (65).
- Set the conveyor function (50)/(51) to "manual" and the auger function (54)/(55) to
"manual". Conveyor and auger start to operate
- Let the hydraulics warm up until the indicator lamp goes out.
A
The Lamp goes out when the pressure drops below
2.8 bar = 40 psi.
For further possible malfunctions, refer to the section "Malfunctions".