D 31 24
Conveyor limit switches -
PLC version
The mechanical conveyor limit switches
(1) or the ultrasonic conveyor limit
switches (2) control the material flow on
the relevant half of the conveyor. The
conveyors should stop when the materi-
al has roughly reached the area below
the auger tube.
A
This requires that the auger height has
been adjusted correctly (see chapter E).
A
In vehicles with a PLC control system,
the deactivation point is set on the re-
mote control.