EasyManua.ls Logo

Dynapac SD2500W - Page 389

Dynapac SD2500W
452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F 61 3
Item
Interval
Maintenance point Note
10
50
100
250
500
1000 / annually
2000 / every 2 years
If necessary
5
g
q
- Hydraulic hoses -
Visual inspection
g
q
- Hydraulic system
Leak test
q
- Hydraulic system
Retighten screw connections
qq
- Hydraulic hoses -
Replace hoses
6 qq
- Auxiliary flow filter-
Replace filter element
(o)
Maintenance q
Maintenance during the running-in period g

Table of Contents

Related product manuals