EasyManua.ls Logo

Endress+Hauser Proline Promass E 500 - Page 181

Endress+Hauser Proline Promass E 500
300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass E 500 PROFIBUS PA Operation
Endress+Hauser 181
Parameter overview with brief description
Parameter Prerequisite Description Selection / User entry / 
User interface
Assign channel 1 The Extended HistoROM application
package is available.
Assign process variable to logging
channel.
Off
Mass flow
Volume flow
Corrected volume flow
*
Density
Reference density
*
Temperature
Oscillation amplitude
*
Current output 1
*
Current output 2
*
Current output 3
*
Current output 4
*
Pressure
GSV flow
*
GSV flow alternative
*
NSV flow
*
NSV flow alternative
*
S&W volume flow
*
Reference density
alternative
*
Water cut
*
Oil density
*
Water density
*
Oil mass flow
*
Water mass flow
*
Oil volume flow
*
Water volume flow
*
Oil corrected volume
flow
*
Water corrected volume
flow
*
Concentration
*
Target mass flow
*
Carrier mass flow
*
Target volume flow
*
Carrier volume flow
*
Target corrected volume
flow
*
Carrier corrected volume
flow
*
Oscillation amplitude
*
HBSI
*
Exciter current 0
Oscillation damping 0
Oscillation damping
fluctuation 0
*
Oscillation frequency 0
Oscillation amplitude
*
Frequency fluctuation 0
*
Oscillation amplitude 1
*
Signal asymmetry
Electronic temperature
Assign channel 2 The Extended HistoROM application
package is available.
The software options currently
enabled are displayed in the
Software option overview
parameter.
Assign a process variable to logging
channel.
For the picklist, see Assign
channel 1 parameter
(→  181)

Table of Contents

Related product manuals