SmartROC T35/T40 17 Compressed Air System
102 No: 7026962571.1.7027002891 en-US
17.5 Check Compressor Components
n
Check for signs of oil or water or air leakage on the compressor (A).
n
Check connections and couplings on intake manifolds (B) on the air filters for com-
pressor and diesel engine.
17.6 Oil Change and Oil Filter Replacement
Oil grade and operating temperature determines the intervals for oil change. The pre-
scribed interval is based on an oil temperature of up to 120 ºC (248 ºF) and normal operat-
ing conditions. Oil must be changed more frequently when working in high ambient temper-
atures or dusty or damp conditions.
The system must be flushed clean before new oil is filled if the oil is
Contaminated by incorrect oil.
Broken down due to excessive temperature.
Used beyond the operating interval.