SmartROC T35/T40 20 Automatic Central Lubrication System CLS
129 No: 7026962571.1.7027002891 en-US
20.4 Filling Lubricant
The container is transparent for visual inspection of the level. The filler nipple (A) is located
directly on the pump.
!
NOTE: Use a filler pump to fill the lubricant.
1.
Remove the protective cover on the nipple (A).
2.
Fill through the nipple (A) to the "MAX" marking on the container. Do not overfill.
3.
Refit the protective cover.
20.5 Testing Central Lubrication System or Starting Extra
Lubrication
This test function makes it possible to check that the timer and the system are working.