SmartROC T35/T40 3 Specifications
13 No: 7026962571.1.7027002891 en-US
3 Specifications
3.1 Standard Tightening Torques Bolted Joints
All bolted joints are tightened to the torque required by Epiroc Standard K 4369:01 K (met-
ric) and 4368K/-01K (imperial) unless otherwise stated. In such cases, this torque is speci-
fied in the maintenance instructions of the module in question.
Size Strength
Class
Torque Tolerance ±
Nm lbf.ft Nm lbf.ft
M6 8.8 8 6 2 1.5
M8 8.8 20 15 5 3.6
M10 8.8 41 30 10 7.3
M12 8.8 73 54 18 13.2
M14 8.8 115 85 25 18.4
M16 8.8 185 136 45 33
M20 8.8 355 262 85 62
M24 8.8 600 443 150 110
M12 x 1.25 10.9 135 100 6 4.4
M16 x 1.25 10.9 315 232 15 11
M18 x 1.25 10.9 460 340 20 15
M6 12.9 14 10 3 2.2
M8 12.9 34 25 8 5.9
M10 12.9 70 52 17 12.5
M12 12.9 120 89 30 22
M14 12.9 195 144 45 33
M16 12.9 315 232 75 55.3
M20 12.9 600 443 150 110.6
M24 12.9 1020 752 250 184.3
Table1: Epiroc Standard Torques
3.2 Type Designation Signs for Ordering Spare Parts
Type designation signs are posted on the larger components. The type designation and se-
rial number must always be stated when ordering spare parts or making inquiries regarding
the machine. Type designations and serial numbers are also specified in a separate docu-
ment, Machine Identification (MI). Spare parts can be ordered from Epiroc.