SmartROC T35/T40 19 Water Mist System
124 No: 7026962571.1.7027002891 en-US
19.3 Draining Water Mist System
1.
Remove bolt from the drain hole (B).
2.
Drain water from water mist tank.
3.
Install the bolt back into the drain hole (B).
4.
Put the machine in drilling mode.
5.
Turn off flushing air.
6.
Run the water mist pump for 20 seconds at full power to purge the water from the
hoses.
7.
Turn on flushing air for a few seconds to blow out the remaining water from the sys-
tem.
19.4 Starting Up Water Mist System from Dry
NOTICE
Damage to the Water Mist System
Filling the water mist tank with dirty water can cause damage to the system.
u Always fill the water mist tank with clean water.
NOTICE
Damage to Water Mist Pump
Risk of damage to water mist pump if it is run without water in the system.
u Do not run the pump without water in the system.
1.
Fill up the water mist tank.