SmartROC T35/T40 13 Diesel Engine
84 No: 7026962571.1.7027002891 en-US
13.21.1 Air Filter Indicator Function
To ensure filter clogging is detected, the function of the air filter indicator must be checked
regularly. This is done by gradually covering the air intake with a piece of wood or similar.
The sensor (A) should then send a signal and the warning symbol or the warning light
should come on. If a warning is not indicated, start by checking the cable connections. If
there are no problems with the connections, then the sensor is faulty and must be re-
placed. The sensor is not included in the filter housing, but is ordered separately.
!
NOTE: Be sure to use an intact and clean piece of wood so that dirt or other particles
do not enter the filter housing.
13.21.2 Check Air Filter Indicator Lamp Function
!
NOTE: Check that no dirt or other particles enter the filter housing.
1.
Remove the air intake cover on the filter housing.