EasyManuals Logo

Epiroc SmartROC T40 Maintenance

Default Icon
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
SmartROC T35/T40 7 Operator Environment
26 No: 7026962571.1.7027002891 en-US
4.
Close the cover and refit the screws.
7.6 Replace Air Condition Circulation Filters
1.
Remove the screws on the covers (A) and (B).
2.
Open the covers (A) and (B) and lift out the filters.
3.
Replace with new filters.
4.
Close the covers (A) and (B) and install the screws.
7.7 Troubleshooting Air Conditioner
Fault Symptom Action
No cooling at all Check the fuses, electrical connections, compressor ground, electro-
magnets, switches, and pressure switches.
Check the V-belt and compressor.
Check the expansion valve and temperature control valve.
Check the coolant hoses.
Poor cooling Check the fresh-air fan and V-belt tension.
Check whether the air is passing the evaporator in the unit.
Check that the evaporator and condenser are not clogged and that the
filter in the air intake is not dirty.
Check that the expansion valve capillary tube is firmly tightened against
the evaporator outlet pipe.
Check that the thermostat does not cut out too early.
Uneven cooling Check that the connections to switches, magnetic coupling, or pressure
switch are not loose.
Check that the expansion valve is not clogged.

Table of Contents

Other manuals for Epiroc SmartROC T40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epiroc SmartROC T40 and is the answer not in the manual?

Epiroc SmartROC T40 Specifications

General IconGeneral
BrandEpiroc
ModelSmartROC T40
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals