EasyManuals Logo

Epiroc SmartROC T40 Maintenance

Default Icon
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
SmartROC T35/T40 13 Diesel Engine
85 No: 7026962571.1.7027002891 en-US
2.
Allow the engine to idle.
3.
Use a piece of board or similar to cover part of the air intake.
4.
Check that the alarm indicator lamp is turned on.
è
The alarm indicator lamp is turned on.
!
NOTE: If an alarm indicator lamp is not turned on, check ca-
ble connections. If there are no problems with the connec-
tions, then the alarm indicator lamp (A) is faulty and must be
replaced.
5.
Stop the engine and reset the alarm indicator lamp (A) by pressing the button on the
indicator lamp.
6.
Install the air intake cover.
13.21.3 Replace Air Filter Cartridge
!
NOTE: Do not clean the filter cartridge.
1.
Remove the clamps (A).
2.
Remove the cover (B).
3.
Remove the filter cartridge (C).
4.
Clean inside the filter housing and lid.
5.
Check the evacuation valve (D).
6.
Install a new filter cartridge (C).
7.
Install the cover (B) and attach the clamps (A).