SmartROC T35/T40 17 Compressed Air System
108 No: 7026962571.1.7027002891 en-US
Air Compressor System
Fault Symptom Possible Faults Action
The compressor is automatically
loaded to full capacity after start-
ing.
The intake valve (A) has jammed
in open position
Remove and inspect the intake
valve, replace parts if necessary.
Air is leaking in the control sys-
tem
Check hoses and connections
for leaks. Stop leaks and replace
leaking hoses.
Freezing problems in the control
circuit
Operate the machine with the in-
take valve (A) activated. Run the
machine to operating tempera-
ture together with the compres-
sor system heating cable. Turn
the valve (A) back after approxi-
mately 15 minutes and check
that the compressor is not
loaded.
The air valve (C) is faulty Check that the contact is con-
nected. Check the air valve for
faults and replace if necessary.
The compressor does not pro-
vide air when flushing or pres-
sure is required
The air valve (C) has no power
supply
Check the electrical wiring and
connection.
The intake valve (A) has jammed
in closed position
Remove and inspect the intake
valve, replace parts if necessary.

Table of Contents

Other manuals for Epiroc SmartROC T40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epiroc SmartROC T40 and is the answer not in the manual?

Epiroc SmartROC T40 Specifications

General IconGeneral
BrandEpiroc
ModelSmartROC T40
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals