SmartROC T35/T40 17 Compressed Air System
110 No: 7026962571.1.7027002891 en-US
Fault Symptom Possible Faults Action
Low oil level Before checking the oil level,
wait for about 30 minutes after
the unit has stopped. Check the
oil level and top up with oil, if
necessary.
The thermostatic safety valve (J)
stalls in closed position
Remove and check the thermo-
stat for the correct opening and
closing temperature. Replace
the valve in the event of incor-
rect function.
Faulty cooling fan Replace the fan.
Temperature sensor (G) faulty Check the temperature sensor
and replace if faulty.
Air emission temperature above
normal value
Compressor element (F) is not in
order
Contact Epiroc