EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY PH ASSY 340
4.4.15 DRIVE ASSY-PH
REMOVAL
1. Remove FRAME ASSY-PH. (p.327)
2. Remove MOTOR-PH. (p.337)
3. Unclamp the clamp on DRIVE ASSY-PH, and remove the harness.
4. Remove the 2 screws (silver, with flange, tapping, 8 mm) fastening DRIVE
ASSY-PH to FRAME ASSY-PH.
5. Remove DRIVE ASSY-PH from FRAME ASSY-PH.
REINSTALLATION
1. Match the hole on DRIVE ASSY-PH with the boss on FRAME ASSY-PH, and
attach DRIVE ASSY-PH.
2. Fasten DRIVE ASSY-PH to FRAME ASSY-PH with the 2 screws (silver, with
flange, tapping, 8 mm).
3. Fasten the harness with the clamp on DRIVE ASSY-PH.
4. Attach MOTOR-PH. (p.337)
5. Attach FRAME ASSY-PH. (p.327)
Figure 4-56. Removal of DRIVE ASSY-PH
C A U T I O N
When performing the following work, make sure that the gears on
CLUTCH ASSY REGI and CLUTCH ASSY PRE REGI are
correctly engaged.
Leg_Sec03_069FA
4)
4)
3)
5)
CLUTCH ASSY REGI
CLUTCH ASSY PRE REGI