EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 352
4.5.6 SWITCH 2BTR COVER
REMOVAL
1. Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
2. Disconnect the connector (P/J113) from SWITCH 2BTR COVER.
3. Remove the screw (silver, tapping, 6 mm) fastening BRACKET-SWITCH 2ND to
COVER-RR 2ND.
4. Remove BRACKET-SWITCH 2ND from COVER-RR 2ND together with
SWITCH 2BTR COVER.
5. Unhook the two hooks fastening SWITCH 2BTR COVER to BRACKET-
SWITCH 2ND, and remove SWITCH 2BTR COVER.
REINSTALLATION
1. Match the hooks on SWITCH 2BTR COVER with the attachment position, and
attach to BRACKET-SWITCH 2ND.
2. Match the hole on BRACKET-SWITCH 2ND with the boss on COVER-RR 2ND,
and attach together with SWITCH 2BTR COVER.
3. Fasten BRACKET-SWITCH 2ND to COVER-RR 2ND with the screw (silver,
tapping, 6 mm).
4. Connect the connector (P/J113) to SWITCH 2BTR COVER.
5. Attach CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
Figure 4-65. Removal of SWITCH 2BTR COVER
Leg_Sec03_071FA
3)
4)
5)-1
5)-2
2)