EasyManua.ls Logo

Epson AcuLaser C1100 - Plate Bias-2 Nd Assy

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 358
4.5.11 PLATE BIAS-2ND ASSY
REMOVAL
1. Remove COVER ASSY RH. (p.301)
2. Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
3. Remove 2ND BTR ASSY. (p.348)
4. Remove the 2 screws (silver, with flange, tapping, 6 mm) fastening PLATE BIAS-
2ND ASSY to the main unit.
5. Unclamp the clamp fastening WIRE ASSY 2BTR, and slightly release PLATE
BIAS-2ND ASSY from the main unit.
6. Remove the screw (silver, tapping, 6 mm) fastening the terminal of WIRE ASSY
2BTR to PLATE BIAS-2ND ASSY.
7. Remove WIRE ASSY 2BTR from PLATE BIAS-2ND ASSY, and remove
PLATE BIAS-2ND ASSY.
Figure 4-70. Removal of PLATE BIAS-2ND ASSY
C A U T I O N
When performing the following work, take care not to remove
PLATE BIAS-2ND ASSY too far as it is connected by WIRE ASSY
2BTR.
Leg_Sec03_150FB
4)
4)
5)-2
6)
7)
5)-1
E ring
SHAFT-CENT 2ND