EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 434
4.12.18 HINGE ASSY L
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove COVER-L DUP. (p.414)
3. Remove the E-ring fastening HINGE ASSY L to DUPLEX ASSY.
4. Remove HINGE ASSY L from DUPLEX ASSY.
REINSTALLATION
1. Match the hole on HINGE ASSY L with the D cut surface on SHAFT HINGE,
insert SHAFT DAMPER between the top and bottom pads of HINGE ASSY L,
and attach HINGE ASSY L.
2. Fasten HINGE ASSY L to DUPLEX ASSY with the E-ring.
3. Attach COVER-L DUP. (p.414)
4. Attach DUPLEX ASSY. (p.412)
Figure 4-134. Removal of HINGE ASSY L
Leg_Sec03_133FA