DISASSEMBLY AND ASSEMBLY PH ASSY 329
4.4.5 CLUTCH ASSY REGI
REMOVAL
1. Remove FRAME ASSY-PH. (p.327)
2. Remove MOTOR-PH. (p.337)
3. Remove DRIVE ASSY-PH. (p.340)
4. Disconnect the connector (P/J203) from CLUTCH ASSY REGI, and remove the
harness of CLUTCH ASSY REGI from the groove on FRAME ASSY-PH.
5. Remove the E-ring fastening CLUTCH ASSY REGI to FRAME ASSY-PH.
6. Remove CLUTCH ASSY REGI from FRAME ASSY-PH.
REINSTALLATION
1. Match the hole position of CLUTCH ASSY REGI with the D cut surface on the
shaft of ROLL-REGI METAL, and attach CLUTCH ASSY REGI so that the
protrusion of FRAME ASSY-PH enters the concave portion on CLUTCH ASSY
REGI.
2. Fasten CLUTCH ASSY REGI to FRAME ASSY-PH with the E-ring.
3. Route the harness of CLUTCH ASSY REGI in the groove on FRAME ASSY-PH,
and connect the connector (P/J203) to CLUTCH ASSY REGI.
4. Attach DRIVE ASSY-PH. (p.340)
5. Attach MOTOR-PH. (p.337)
6. Attach FRAME ASSY-PH. (p.327)
Figure 4-46. Removal of CLUTCH ASSY REGI
C A U T I O N
Step numbers with [ ] in the figure indicate the step of
reinstallation.
C A U T I O N
When performing the following work, leave the intermediate
connector on the harness side.
Leg_Sec03_058FA
4)
6)
5)
[3)-1]
[3)-2]