DISASSEMBLY AND ASSEMBLY PH ASSY 326
4.4.3 CHUTE-REAR UP, CHUTE-REAR LOW
REMOVAL
1. Remove CHUTE ASSY-REAR. (p.325)
2. Remove the 2 screws (silver, with flange, tapping, 8 mm) fastening CHUTE-
REAR LOW to CHUTE-REAR UP.
3. Remove the concave portion on CHUTE-REAR LOW from the protrusion on
CHUTE-REAR UP, and remove CHUTE-REAR LOW from CHUTE-REAR UP.
REINSTALLATION
1. Match the hole on CHUTE-REAR LOW with the boss on CHUTE-REAR UP, and
insert the protrusion on CHUTE-REAR UP into the concave portion on CHUTE-
REAR LOW to attach.
2. Fasten CHUTE-REAR LOW to CHUTE-REAR UP with the 2 screws (silver, with
flange, tapping, 8 mm).
3. Attach CHUTE ASSY-REAR. (p.325)
Figure 4-42. Removal of CHUTE-REAR UP and CHUTE-REAR LOW
C A U T I O N
Step numbers with [ ] in the figure indicate the step of
reinstallation.
C A U T I O N
The protrusion on CHUTE REAR UP must be inserted firmly into
the concave portion on CHUTE-REAR LOW.