EasyManua.ls Logo

Epson AcuLaser C1100 - Motor Assy Dup

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 443
4.12.26 MOTOR ASSY DUP
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove COVER-L DUP. (p.414)
3. Unclamp the clamp on BKT MOTOR DUP TRANS, and remove the harness.
4. Disconnect connector (P/J444) from PWBA DUP-L.
5. Remove the 4 screws (silver, with flange, tapping, 10 mm) fastening BKT
MOTOR DUP TRANS to DUPLEX ASSY.
6. Remove BKT MOTOR DUP TRANS from DUPLEX ASSY together with PWBA
DUP-L and MOTOR ASSY DUP.
7. Unclamp the clamp, and disconnect connector (P/J442) of MOTOR ASSY DUP
on PWBA DUP-L.
8. Remove the 4 screws (silver, 5mm) fastening MOTOR ASSY DUP to BKT
MOTOR DUP TRANS.
9. Remove MOTOR ASSY DUP from BKT MOTOR DUP TRANS.
Figure 4-143. Removal of MOTOR ASSY DUP (1)
C A U T I O N
When performing the following work, take care not to remove
DUPLEX ASSY and BKT MOTOR DUP TRANS too far as
they are connected by a harness.
When performing the following work, take care not to drop or
lose gears, and other parts.
Leg_Sec03_128FB
4)
3)
5)
5)
5)
5)
6)