EasyManua.ls Logo

Epson AcuLaser C1100 - Cap-Plate Pr, Plate-Assy Pr

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY XERO 371
4.6.7 CAP-PLATE PR, PLATE-ASSY PR
REMOVAL
1. Remove COVER ASSY RH. (p.301)
2. Remove 2ND BTR ASSY. (p.348)
3. Remove FRAME ASSY-PH. (p.327)
4. Remove BCR CLN XERO ASSY. (p.373)
5. Remove SENSOR TR-0. (p.361)
6. Remove GUIDE CRU ASSY AD. (p.367)
7. Remove LEVER-LATCH PR. (p.370)
8. Turn PLATE-ASSY PR in the direction of the arrow, match the notch on PLATE-
ASSY PR with the protrusion on GUIDE CRU ASSY AD, and remove PLATE-
ASSY PR together with CAP-PLATE PR.
9. Unhook the hook on CAP-PLATE PR, and remove CAP-PLATE PR from
PLATE-ASSY PR.
REINSTALLATION
1. Attach CAP-PLATE PR to PLATE-ASSY PR.
2. Match the notch on PLATE-ASSY PR with the protrusion on GUIDE CRU ASSY
AD, and attach PLATE-ASSY PR together with CAP-PLATE PR.
3. Attach LEVER-LATCH PR. (p.370)
4. Attach GUIDE CRU ASSY AD. (p.367)
5. Attach SENSOR TR-0. (p.361)
6. Attach BCR CLN XERO ASSY. (p.373)
7. Attach FRAME ASSY-PH. (p.327)
8. Attach 2ND BTR ASSY. (p.348)
9. Attach COVER ASSY RH. (p.301)
Figure 4-82. Removal of CAP-PLATE PR and PLATE-ASSY PR
C A U T I O N
When performing the following work, pay attention to the
attachment direction of CAP-PLATE PR.
Leg_Sec03_203FA
9)-2
9)-1
8)

Table of Contents

Other manuals for Epson AcuLaser C1100

Related product manuals