EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY COVER 288
4.2.6 SWITCH ASSY TOP
REMOVAL
1. Remove COVER ASSY RH. (p.301)
2. Unclamp the two clamps fastening the harness of SWITCH ASSY TOP, and
remove the harness.
3. Disconnect connector (P/J116, blue) of SWITCH ASSY TOP.
4. Remove the screw (silver, with flange, 8 mm) fastening SWITCH ASSY TOP to
the main unit.
5. Remove SWITCH ASSY TOP from the main unit.
REINSTALLATION
1. Match the hole on SWITCH ASSY TOP with the boss on the main unit, and
attach.
2. Fasten SWITCH ASSY TOP to the main unit with the screw (silver, with flange, 8
mm).
3. Connect connector (P/J116, blue) of SWITCH ASSY TOP.
4. Clamp the harness of SWITCH ASSY TOP with the two clamps.
5. Attach COVER ASSY RH. (p.301)
Figure 4-8. Removal of SWITCH ASSY TOP
C A U T I O N
When performing the following work, leave the intermediate
connector (blue) on the harness side.
Leg_Sec03_006EB
4)
3)
2)
2)
(blue)
(Blue)
Intermediate connector