EasyManua.ls Logo

Epson AcuLaser C1100 - Sensor Upper Pass

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 422
4.12.9 SENSOR UPPER PASS
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove COVER-R DUP. (p.413)
3. Remove COVER-L DUP. (p.414)
4. Remove LINK-LATCH and LINK-BUTTON. (p.416)
5. Open COVER UP-DUP TRANS, and remove INVERTER ASSY DUP. Note that
COVER LOW-DUP TRANS and COVER UP-DUP TRANS need not be
removed. (p.417)
6. Remove COVER-INV. (p.415)
7. Remove the screw (silver, with flange, tapping, 10 mm) fastening BRACKET-
SNS to INVERTER ASSY DUP.
8. Remove BRACKET-SNS from INVERTER ASSY DUP together with SENSOR
UPPER PASS.
9. Disconnect connector (P/J124) from SENSOR UPPER PASS.
10. Unhook the 3 hooks fastening SENSOR UPPER PASS to BRACKET-SNS, and
remove SENSOR UPPER PASS.
Figure 4-124. Removal of SENSOR UPPER PASS
Leg_Sec03_124FA
10)-1
7)
8)
9)
10)-2