DISASSEMBLY AND ASSEMBLY TRANSFER 341
4.5 TRANSFER
4.5.1 CHUTE ASSY-FSR, COVER ASSY-RR 2ND
REMOVAL
CHUTE ASSY-FSR.
1. Open CHUTE ASSY-FSR.
2. Press the hinge on CHUTE ASSY-FSR to the inside with a flat-blade screwdriver
or a similar tool, and remove CHUTE ASSY-FSR from the main unit.
3. Disconnect the connector (P/J620) from CHUTE ASSY-FSR connected to the
main unit.
Figure 4-57. Removal of CHUTE ASSY-FSR
C A U T I O N
When performing the following work, take care not to remove
CHUTE ASSY-FSR too far as it is connected by a harness.
C A U T I O N
When performing the following work, leave the intermediate
connector on the harness side.
C H E C K
P O I N T
When HARNESS ASSY 2BTR SW need not be removed in the
following procedure, COVER ASSY-RR 2ND can be removed
without removing COVER ASSY LH by disconnecting connector
(P/J113) from SWITCH 2BTR COVER instead of connector (P/
J621).