EasyManua.ls Logo

Epson AcuLaser C1100 - Clutch Assy Pre Regi

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY PH ASSY 338
4.4.13 CLUTCH ASSY PRE REGI
REMOVAL
1. Remove FRAME ASSY-PH. (p.327)
2. Remove MOTOR-PH. (p.337)
3. Remove DRIVE ASSY-PH. (p.340)
4. Disconnect the connector (P/J202) from CLUTCH ASSY REGI, and remove the
harness of CLUTCH ASSY REGI from the groove on FRAME ASSY-PH.
5. Remove the E-rings fastening CLUTCH ASSY PRE REGI to FRAME ASSY-PH.
6. Remove CLUTCH ASSY PRE REGI from FRAME ASSY-PH, and remove the
harness of CLUTCH ASSY PRE REGI from the hole on FRAME ASSY-PH.
REINSTALLATION
1. Insert the harness of CLUTCH ASSY PRE REGI into the hole on FRAME ASSY-
PH.
2. Match the hole position of CLUTCH ASSY PRE REGI with the D cut surface on
the shaft of ROLL ASSY-PRE REGI, and attach CLUTCH ASSY PRE REGI so
that the protrusion on FRAME ASSY-PH enters the concave portion on CLUTCH
ASSY PRE REGI.
3. Fasten CLUTCH ASSY PRE REGI to FRAME ASSY-PH with an E-ring.
4. Route the harness of CLUTCH ASSY PRE REGI in the groove on FRAME
ASSY-PH, and connect the connector (P/J202) to CLUTCH ASSY PRE REGI.
5. Attach DRIVE ASSY-PH. (p.340)
6. Attach MOTOR-PH. (p.337)
7. Attach FRAME ASSY-PH. (p.327)
Figure 4-54. Removal of CLUTCH ASSY PRE REGI
C A U T I O N
Step numbers with [ ] in the figure indicate the step of
reinstallation.
C A U T I O N
When performing the following work, do not disconnect the relay
connectors.