EasyManua.ls Logo

Epson AcuLaser C1100 - Latch Dup R, Latch Dup L

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY DUPLEX 428
4.12.13 LATCH DUP R, LATCH DUP L
REMOVAL
1. Remove DUPLEX ASSY. (p.412)
2. Remove COVER-R DUP. (p.413)
3. Remove COVER-L DUP. (p.414)
4. Remove LINK-LATCH and LINK-BUTTON. (p.416)
5. Unclamp the clamp on BKT MOTOR DUP TRANS, and remove the harness.
6. Disconnect connector (P/J444) from PWBA DUP-L.
7. Remove the 4 screws (silver, with flange, tapping, 10mm) fastening BKT
MOTOR DUP TRANS to DUPLEX ASSY.
8. Remove BKT MOTOR DUP TRANS from DUPLEX ASSY together with PWBA
DUP-L and MOTOR ASSY DUP.
9. Remove SPRING LATCH from LATCH DUP R.
10. Remove the screw (silver, with flange, tapping, 10 mm) fastening LATCH DUP L
to DUPLEX ASSY.
11. Turn LATCH DUP R and LATCH DUP L, match the protrusions on LATCH
DUP R and LATCH DUP L with the notches of hole on DUPLEX ASSY, and
remove LATCH DUP R and LATCH DUP L.
Figure 4-128. Removal of LATCH DUP R and LATCH DUP L (1)
C A U T I O N
When performing the following work, take care not to remove
DUPLEX ASSY and BKT MOTOR DUP TRANS too far as
they are connected by a harness.
When performing the following work, take care not to drop or
lose gears, and other parts.
Leg_Sec03_128FB
5)
6)
7)
7)
7)
7)
8)