EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY XERO 362
4.6.2 GUIDE CRU ASSY D
REMOVAL
1. Remove 2ND BTR ASSY. (p.348)
2. Remove COVER ASSY LH. (p.295)
3. Remove PWBA MCU. (p.404)
4. Remove CHASSIS ASSY ESS. (p.411)
5. Remove SENSOR TR-0. (p.361)
6. Remove the 2 screws (silver, with flange, tapping, 6 mm) fastening PLATE-TR-0
to GUIDE CRU ASSY D and GUIDE CRU ASSY AD.
7. Remove PLATE-TR-0 from GUIDE CRU ASSY D and GUIDE CRU ASSY AD.
Figure 4-73. Removal of GUIDE CRU ASSY D (1)
C H E C K
P O I N T
When performing the following work, connectors need not be
disconnected from PWBA ESS.
Leg_Sec03_077EB
6)
7)
6)