EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY XERO 363
8. Unclamp the clamp fastening HARNESS-ASSY XERO on the left side of the
main unit.
9. Remove the 5 screws (silver, with flange, tapping, 6 mm) fastening GUIDE CRU
ASSY D to the main unit.
10. Remove GUIDE CRU ASSY D from the main unit.
REINSTALLATION
1. Insert HARNESS-ASSY XERO into the hole on the left side of the main unit, and
match the boss on GUIDE CRU ASSY D into the hole on the main unit to attach
GUIDE CRU ASSY D.
2. Fasten GUIDE CRU ASSY D to the main unit with the 5 screws (silver, with
flange, tapping, 6 mm).
3. Fasten HARNESS-ASSY XERO on the left side of the main unit with the clamp.
4. Attach PLATE-TR-0 to GUIDE CRU ASSY D and GUIDE CRU ASSY AD.
5. Fasten PLATE-TR-0 to GUIDE CRU ASSY D and GUIDE CRU ASSY AD with
the 2 screws (silver, with flange, tapping, 6 mm).
6. Attach SENSOR TR-0. (p.361)
7. Attach CHASSIS ASSY ESS. (p.411)
8. Attach PWBA MCU. (p.404)
9. Attach COVER ASSY LH. (p.295)
10. Attach 2ND BTR ASSY. (p.348)
Figure 4-74. Removal of GUIDE CRU ASSY D (2)
C A U T I O N
Lightly open/close COVER ASSY TOP, and check operation of the
coupling on MOT ASSY P/R.
Leg_Sec03_078EB
10)
8)
9)
9)
9)
9)
9)
MOT ASSY P/R

Table of Contents