 Align the positioning holes (x1) of the Main Board Unit with the 
dowels (x1) of the Base Frame. (See 
Fig. 4-42.)
 Align the dowels (x2) of the Main Board Unit with the 
positioning holes (x2) of the Holder IC Shield Plate. (See 
Fig. 
4-42.)
 Align the dowel (x1) of the Main Board Unit with the 
positioning hole 
(x1) of the Right Cable Frame.
 (See
 
Fig. 4-42.)
 Insert the rib (x1) of the Grounding Plate M/B to the hole of the 
Main Board Unit, and align the positioning hole (x1) of the 
Grounding Plate M/B with the dowel (x1) of the Main Board 
Unit, and then attach the Grounding Plate M/B. (See 
Fig. 4-42, 
Fig. 4-43.)
Figure 4-43.  Attaching the Grounding Plate M/B
Hole
Rib
Grounding Plate M/B
 When attaching the CR Encoder FFC, follow the procedure 
below.
1. Put the CR Encoder FFC through the ferrite core.
2. Connect the CR Encoder FFC to the connector (CN6) on 
the Main Board.
3. Insert the rib of the Ferrite Core Holder B to the hole of the 
Main Board, and secure it with the screw (x1).
Figure 4-44.  Attaching the CR Encoder FFC
 For routing cables and FFCs, see "4.4 Routing FFC/cables" 
(p.196).
C.B.S. 3x6 (5±0.5Kgfcm)
CN6
CR Encoder FFC
Ferrite core
Ferrite Core Holder B
Align and insert the rib of 
the Ferrite Core Holder B