System 5 Digital Audio Mixing System Operation Manual eMix Application
45
For each ML530, PatchNet needs to know which MADI input the AM713 is connected
to so the mic preamp parameters appear on the corresponding input channel knobset.
For each Mic/Line Interface, note how it is connected. In the example that follows, the
MADI output from the Analog to MADI converters of two ML530 Mic/Line interfaces
have been connected to the inputs of Frame1-1 and Frame1-2.
1. Select Cabling in PatchNet.
2. Select the MADI Out Ports sub-category.
The list shows 7 Mic/Line Interfaces but only configure those wired to the Hub
(i.e., Mic1 and Mic2).
3. Click and drag through the cells to the right of Mic1 and Mic2.
The cells highlight green and the names appear in the Sources column of the
Selected: window below.
4. Select the MADI In Ports sub-category.
5. Click and drag through the cells to the right of the two Frame1 inputs
(Frame 1-1 and Frame1-2).
The cells highlight blue and the names appear in the Destinations column of
the Selected: window below.
6. Click the Patch button to make the patch.
PatchNet now knows how the two mic/line interfaces are connected so the proper input
parameters appear at the top of the channels they are connected to.
Because Frame1-1 and Frame1-2 have been designated as MADI connections to the
Mic/Line interfaces, clicking on the Frame1-1 and Frame1-2 sub-categories in the
Sources show Device Patch in the first 24 cells and will not allow selection unless
they are unpatched.
4.2.4 Patching Examples
Patch 12 mics into channels 25–36
Select the Sources
1. Click on Sources from the four PatchNet categories.
2. Click on Mic 1 from the sub-categories.
This displays all inputs in the center of the window from the first Mic-Line Inter-
face. The Mic-Line Interface will be connected as part of the initial studio
setup.