208 UMFLUXUS_G6V4-2EN, 2011-03-29
FLUXUS G60x B Technical Data
explosion protection
A
T
E
X
transducer GSG-NA2NL GSK-NA2NL GSM-NA2NL GSP-NA2NL
category
EPL
zone
gas: 3G dust: 2D
Gc Db
2 21
gas: 3G dust: 2D
Gc Db
2 21
explosion protection temperature (pipe surface)
min. °C -55 -55 -55 -55
max. °C +190 +190 +190 +190
marking
0637
II3G Ex nA IIC
T6...T2 Gc X
II2D Ex tb IIIC TX
Db
0637
II3G Ex nA IIC
T6...T2 Gc X
II2D Ex tb IIIC TX
Db
0637
II3G Ex nA IIC
T6...T2 Gc X
II2D Ex tb IIIC TX
Db
0637
II3G Ex nA IIC
T6...T2 Gc X
II2D Ex tb IIIC TX
Db
certification IBExU10ATEX1
163 X
IBExU10ATEX1
163 X
IBExU10ATEX1
163 X
IBExU10ATEX1
163 X
type of protection gas: non spar-
king
dust: protection
by enclosure
gas: non spar-
king
dust: protection
by enclosure
gas: non spar-
king
dust: protection
by enclosure
gas: non spar-
king
dust: protection
by enclosure
necessary trans-
ducer mounting
fixture
--- -
1
depending on application, typical absolute value for natural gas, nitrogen, compressed air
2
shear wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended/max. extended: in diagonal mode and for a
flow velocity of 15 m/s
technical type GDG1NH1 GDK1NH1 GDM2NH1 GDP2NH1

Table of Contents