Remote Operation
SCPI Commands and Syntax 5
5-21
Keyword Parameter Form Notes
INPut
:DIP
:TRIGger [No query form]
[SOURce]
:FREQuency(?) <dnpd>
:LINE(?) <bool> {OFF | ON | 0 | 1}
:LOCKed?
:POWer
:UNBalanced? Query only.
:STANdard(?) [<cpd> { NEMA | IEC }]
:BUDeanu? [<cpd>{DELTa|WYE}, <cpd> { P | S | Q | D |PF}]
:FLICker
:STANdard(?) [<cpd> { STD1 | STD2 }]
:TERMinal
[:STATe](?) <bool> {OFF | ON | 0 | 1}
:ROUTe(?) <cpd>{ UPPer | LOWer }
:PHASe<x> <x> is phase (1 to 4).
1 is master phase.
:FITTed(?)
:SERial? Serial number of phase.
:MODel? Model number of phase.
:POWer
[:WATTs]?
:VA?
:PFACtor?
:BUDeanu? [<cpd> { P | S | Q | D}]
:FRYZe? [<cpd> { P | S | Q}]
:KUSTers? [<cpd> { P | S | QC | QCR | QL | QLR}]
:SHEPherd? [<cpd> { P | S | SR | SX | SD}]
:SHARon? [<cpd> { P | S | SQ | SC}]
:IEEE? [<cpd> { P | S | N | SN | P1 | S1 | Q1 | PH | SH | NH}]
:VOLTage
[:STATe](?) <bool> {OFF | ON | 0 | 1}
:RANGe <dnpd>, <dnpd> <dnpd> = Low limit, High limit.
:RANGe? [<cpd> {LOW | HIGH}]
:AMPLitude? Absolute final output amplitude.
Query only.
:MHARmonics
[:STATe](?) <bool> {OFF | ON | 0 | 1}
:CLEar
:AMPLitude(?) <dnpd> <dnpd> = RMS amplitude.

Table of Contents