Calibration
Calibration Adjustment Points 7
7-17
Table 7-9. Current Adjustment Points
Range
(Amps)
Fundamental
Frequency
(Hz)
Harmonic
Number
Frequency
(Hz)
Point
Output
Level
Setting
(Amps)
Output Phase
Angle Setting
(Degrees)
0 0
DC
offset
0.000 0
1 57 Gain 0.225 0
57
15 855 Gain 0.225 0
48 3024 Gain 0.200 0
0.25
63
95 5985 Gain 0.125 0
0 0
DC
offset
0.000 0
1 57 Gain 0.450 0
57
15 855 Gain 0.450 0
48 3024 Gain 0.400 0
0.5
63
95 5985 Gain 0.250 0
0 0
DC
offset
0.000 0
1 57 Gain 0.900 0
57
15 855 Gain 0.900 0
48 3024 Gain 0.800 0
1
63
95 5985 Gain 0.500 0
0 0
DC
offset
0.000 0
1 57 Gain 1.800 0
57
15 855 Gain 1.800 0
48 3024 Gain 1.600 0
2
63
95 5985 Gain 1.000 0
0 0
DC
offset
0.000 0
1 57 Gain 4.500 0
8 456 Gain 4.500 0
57
15 855 Gain 4.500 0
48 3024 Gain 4.000 0
5
63
95 5985 Gain 2.500 0
0 0
DC
offset
0.000 0
1 57 Gain 9.000 0
8 456 Gain 9.000 0
15 855 Gain 9.000 0
57
27 1539 Gain 8.000 0
48 3024 Gain 8.000 0
69 4347 Gain 5.000 0
80 5040 Gain 5.000 0
10
63
95 5985 Gain 5.000 0