5-20
Next page
3
Press the POSITION (
▲
) key.
ARMS setting screen (4/4) is displayed.
Supplement
It will return to ARMS setting screen (4/4)
without changing the settings when you press
the POSITION (
◄
) key (CANCEL).
Detection level will define the threshold to be
placed at what percentage point of the signal
level difference between the media background
color and the registration mark. So the setting
range becomes 30 to 90 (%).
X sets the level to detect the registration mark
when moving in the X direction, and Y sets
the level to detect the registration mark when
moving in the Y direction.
l
l
l
4
Press the [3] key (SENSING LEVEL).
SENSING LEVEL adjusting screen is displayed.
Supplement
It will ignore the dust and bumps on the media
surface, but it will make the detection of the
registration harder mark if the value of the
"SENSING LEVEL" is set to larger number. The dust
and bumps on the media surface might be detected
as registration mark by mistake if the value of the
"SENSING LEVEL" is set to smaller number.
5
Press the [1] key (X).
SENSING LEVEL X adjusting screen is displayed.
Supplement
Setting range is from 30 to 90.
6
Press the POSITION (
▲▼
) key and increase or decrease the
setting value.
7
Confirm the setting and press the POSITION (
◄
) key
(PREVIOUS).
SENSING LEVEL is selected and it will return to SENSING LEVEL
adjusting screen.
8
Press the [2] key (Y).
SENSING LEVEL Y adjusting screen is displayed.
Supplement
Setting range is from 30 to 90.
9
Press the POSITION (
▲▼
) key and increase or decrease the
setting value.