Error Messages for ARMS
Symptom LCD Display Possible Cause Solution
E04001 Tilt to adjust with AXIS
ALIGNMENT is too large.
Reload the media.
E04002 It is over the setting range of the
distance adjust.
Reset to smaller value.
E04003 Failed to adjust the sensor level. This media cannot be used.
E04004 It is over the setting range of the
distance adjust.
Reset to smaller value.
E04005 Could not scan the registration
marks.
Check the registration scan
position.
E04006 Amount of data has exceeded the
I/O buffer size for the segment
area registration mark.
Decrease the data.
E04007 Test pattern plotting position is not
within the plotting area for sensor
position adjustment.
Move the media toward center
and plot the test pattern.
E04008 Media end was detected while
detecting the registration mark.
Check the media. Check the print
position of the registration mark.
E04009 It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.
E04010 It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.