11-6
11-7
Enabling/Disabling the ":" and ";" Commands (COMMAND ":",";")
If the first part of the data is lost when the GP-GL command is set, these commands may be having an adverse
effect. In this case, set the ":" and ";" commands to DISABLED.
Operation
1
Press the [MENU] key in the default screen.
MENU screen is displayed.
2
Press the POSITION (
) key (I/F).
POSITION
INTERFACE setting screen (1/3) is displayed.
3
Press the POSITION (
) key.
POSITION
INTERFACE setting screen (2/3) is displayed.
4
Press the [3] key (COMMAND ":",";").
COMMAND ":",";" setting screen is displayed.
5
Press the [1] key (ENABLED) or the [2] key (DISABLED).
6
Confirm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to INTERFACE setting screen (2/3).
7
Press the [MENU] key.
It will return to the default screen.