13-7
Error Messages in HP-GL Command Mode
If any of the following command errors occur, they are nearly always caused by following 2 reasons.
1. The configuration regarding the output device in the application software has changed.
2. The plotter's interface conditions have changed.
Perform following if these are the cause of the problem.
1. Reconfigure the output device of the application software to the plotter.
2. Reconfigure the plotter's interface conditions.
Error
Displayed
LCD Display Cause Solution
E03001 An unrecognizable instruction was
executed.
Execute a recognizable command.
E03002 Wrong number of parameters
were specified.
Execute the command with the
correct number of parameters.
E03003 An unusable parameter was
executed.
Execute a recognizable parameter.
E03005 An unusable character set was
specified.
Specify usable character set.
E03006 The data being input exceeds
the capacity of the plotter's
downloadable character buffer,
polygon buffer, etc.
Execute coordinates within the
cutting area.
E03007 Coordinates of command
specified out of cutting area.
Adjust the buffer size.
E03010 Other output command was
executed while executing an
output command.
Check the program.
E03011 An invalid byte was received after
ESC code.
Check the program.
E03012 Invalid byte was received within
device control command.