Adjust with 3POINTS
3POINTS adjustment will scan 3 registration marks as shown below, where the adjustment is done measuring
the tilting of the X and Y axes and the distance between the registration marks (horizontal and vertical
directions). This adjustment is called 2 axis adjustment (tilt adjustment).
If the loaded media is tilted as shown below, position of the scanned registration mark is shifted from the
position where it should be. Tilt and distance can be adjusted by comparing these coordinate values.
Original registration mark position
Tilt
Second registration mark
Difference in Y
First registration mark
Difference in X
Feed direction of media
Third registration mark
Difference in Y
Tilt
Original registration
mark position
Difference in X
Next page
Operation
Supplement
See "Loading Media (Paper or Marking Film)"
P.2-6
for loading the media.
1
Load the media with registration marks (3POINTS) plotted.
2
Set the MARK SCAN MODE to ARMS, and POINTS to
2POINTS.
P.5-6
Setting MARK SCAN Mode and Numbers
Supplement
It is not necessary to set the MARK DISTANCE
when it is adjusted manually.
3
Set the shape and size of the registration mark, mark distance,
distance adjust mode, offset, paper-weight, sensor level, scan
position adjustment, etc., as needed.
P.5-9
Setting Shape (Pattern) of Registration Mark
P.5-11
Setting Registration Mark Size
P.5-12
Setting Mark Distance
P.5-14
Setting Distance Adjustment Between the Registration Mark
P.5-16
Setting Offset Between the Registration Mark and Cutting Origin Points
P.5-18
Adjusting the Sensor Level
P.5-19
Manually Adjusting the Sensor Level (Threshold Value)
P.7-21
Setting Paper-Weight
4
Press the [MENU] key.
MENU screen is displayed.

Table of Contents

Other manuals for GRAPHTEC FC8000 Series

Related product manuals