5-35
2
Press the POSITION (
▲▼◄►
) key and move the tool carriage
to the area to start scanning of the registration mark.
Supplement
Left figure is for 4POINTS. Size and position of the
registration scan start area is same for 2POINTS
or 3POINTS.
MARK TYPE 1 MARK TYPE 2
Point
4
Point
2
Point
3
Point 1
(point to make
origin point)
Point 1
(point to make
origin point)
Point
4
Point
2
Point
3
Feed direction of media
Mode the tool inside this
area
Mode the tool inside this
area
Feed direction of media
Registration mark scan area
Supplement
Scan the registration marks in accordance
with the setting of the MARK DISTANCE (see
"Setting Mark Distance"
P.5-12
).
It will return to ARMS setting screen (1/4)
without scanning when you press the [4] key
(CANCEL).
l
l
3
Confirm the position of the tool, and if it is OK, press the [ENTER]
key (SET).
Registration marks are scanned automatically. DISTANCE entry screen is
displayed once the scanning is completed.
Supplement
Measured distance is displayed in the top line in
the DISTANCE input screen. Input value (initially
same as measured value) is displayed under
that.
If the input value is not changed, it will assume
that there is no difference between measured
distance and the distance in the data.
Digits of settings can be changed by pressing
the [FAST] key.
l
l
l
4
Press the POSITION (
▲▼
) key and increase or decrease the
setting value.
Supplement
It will return to ARMS setting screen (1/4)
without changing the settings when you press
the POSITION (
◄
) key (CANCEL).
Distance input screen for point 3 is displayed if
it is set to 3POINTS or more, so repeat steps 4
and 5 to set.
l
l
5
Confirm the setting and press the [ENTER] key (SET).
Adjustment by scanning the registration mark is completed, and it will return