Loading...
14-14
14-15
Next page
9
Using the "+" plotted by tool 1, measure the distance to the "+"
plotted by tool 3.
Feed direction of media
Y
X
Y mm
X mm
Tool 1
Tool 2
10
Press the [3] key (X).
X AXIS ALIGNMENT setting screen is displayed.
11
Press the POSITION (
▲▼
) key to increase or decrease the
value to set the difference in X axis direction measured in step
9.
POSITION
12
Confirm the setting and press the POSITION (
) key
(PREVIOUS).
POSITION
X AXIS ALIGNMENT is selected and return to the TOOL OFFSET
ADJ. screen.
13
Press the [4] key (Y).
Y AXIS ALIGNMENT setting screen is displayed.
14
Press the POSITION (
▲▼
) key to increase or decrease the
value to set the difference in Y axis direction measured in step
9.
POSITION
15
Confirm the setting and press the POSITION (
) key
(PREVIOUS).
POSITION
Y AXIS ALIGNMENT is selected and return to the TOOL OFFSET
ADJ. screen.
16
Repeat steps 5 to 15 until there is no difference.
17
Confirm the distance and press the [ENTER] key (SET).
Setting will be set, and it will return to TOOLS SETTING screen (1/3).