TITRATION THEORY
Endpoint
The point were a titration is stopped because a physical change in the solution has
indicated a completed titration. Titration endpoints typically coincide with the equiva-
lence point. A fixed value endpoint (pH or mV) can be used as well. The titration will
stop at the desired point regardless if the titration is complete.
Equivalence point
The point where the quantity of titrant is stoichiometrically equal to the quantity of
analyte.
Formal
The theoretical number of equivalents per liter of the solution.
It is used in solutions
where the exact concentration of a species may be affected by the other ions present,
therefore the stated concentration may not be exactly correct.
Gravimetric Analysis
A quantitative determination of an analyte based on the mass of the solid.
Indicator Electrode
An electrode that responds to the species of interest. The electrode potential is
proportional to the concentration or activity of that ion in the solution being measured.
Indicators
Chemical indicators are typically organic dyes that change form under different physical
conditions, causing a color change that can be seen by an analyst. Typically used in
manual titrations, chemical indicators have been replaced with electrometric indicators,
which are used with automatic titrators.
Inflection Point
The point on a titration curve were the second derivative curve changes signs.
Ion Selective Electrode (ISE)
An electrode that responds to a specific ion. The electrode potential is proportional to
the concentration or activity of that ion in the solution being measured.
Karl Fischer Titration
A titration that uses a chemical reaction that is specific for determining water.
Manual Titration
A titration that is carried out by hand. The analyst must add the appropriate amount
of titrant, determine the endpoint and calculate the results.
Molar
The concentration of a solute in a solution.
Mole (mol)
A quantity of a chemical species. The molecular weight of a substance in grams is
equal to the mass of one mole of the substance. One mole is equal to 6.022 x 10
23
atoms or molecules.
Monochromator
A device that allows only a narrow range of wavelengths to pass though it by separating
the light into different wavelengths.
Multiple Endpoint Titration
A titration that reacts multiple species in solution sequentially using the same titrant.
The concentration of each analyte can be determined from their respective endpoints.
Nernst Equation
The fundamental equation relating cell voltage to the concentration of a solution.
sale@ponpe.com
www.ponpe.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 902 Color and is the answer not in the manual?

Hanna Instruments HI 902 Color Specifications

General IconGeneral
BrandHanna Instruments
ModelHI 902 Color
CategoryTest Equipment
LanguageEnglish

Related product manuals